{"id":16433,"date":"2024-05-05T23:02:19","date_gmt":"2024-05-05T20:02:19","guid":{"rendered":"https:\/\/cmcpal.com\/site\/?post_type=product&#038;p=16433"},"modified":"2024-05-13T12:27:30","modified_gmt":"2024-05-13T09:27:30","slug":"electrocardiograph-ecg1212g","status":"publish","type":"product","link":"https:\/\/cmcpal.com\/site\/product\/electrocardiograph-ecg1212g\/","title":{"rendered":"Electrocardiograph \/ ECG1212G"},"content":{"rendered":"<div><a href=\"https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/05\/ECG1212G.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-14297\" src=\"https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-300x300.png\" alt=\"\" width=\"64\" height=\"64\" srcset=\"https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-300x300.png 300w, https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-200x200.png 200w, https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-150x150.png 150w, https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf.png 512w\" sizes=\"(max-width: 64px) 100vw, 64px\" \/><\/a><a href=\"https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/05\/ECG1212G-2.pdf\"><img decoding=\"async\" class=\"alignnone wp-image-14297\" src=\"https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-300x300.png\" alt=\"\" width=\"64\" height=\"64\" srcset=\"https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-300x300.png 300w, https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-200x200.png 200w, https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf-150x150.png 150w, https:\/\/cmcpal.com\/site\/wp-content\/uploads\/2024\/04\/file-pdf.png 512w\" sizes=\"(max-width: 64px) 100vw, 64px\" \/><\/a><\/div>\n<div>\n<div class=\"row\">\n<div class=\"col-xl-10 mx-auto\">\n<div id=\"myTabContent\" class=\"tab-content\">\n<div id=\"description\" class=\"tab-pane fade show active\" role=\"tabpanel\" aria-labelledby=\"description-tab\">\n<div class=\"p-3 p-md-5\">\n<h2><strong>Electrocardiograph Touch Screen<\/strong><\/h2>\n<blockquote><p>ECG1212G<\/p><\/blockquote>\n<div>\n<p>The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto \/ manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for \u201cLead off\u201d and \u201cLack of paper\u201d; optional interface language (Chinese \/ English, etc.); built-in lithium battery, AC \/ DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management.<\/p>\n<p><strong>Functions :<\/strong><\/p>\n<\/div>\n<ol>\n<li>\u00a0Adopt 10.1&#8221; high-resolution color LCD, operate by full-touch screen and function bu ttons, convenient to use.<\/li>\n<li>\u00a0Sync collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via power frequency filter (50 \/ 60 Hz), baseline filter and EMG filter (25 \/ 35 Hz) of ECG signal.<\/li>\n<li>\u00a0Display 3 \/ 6 \/ 12 &#8211; lead ECG waveform, HR value, print mode, sensitivity, paper speed, filter state, clock, battery power, background grid, measured parameter and interpretation, etc. on one screen, and with prompt functions for lead &#8211; off, overload and system working state.<\/li>\n<li>\u00a0Power supply: AC \/ DC (which can adapt AC 50 \/ 60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.<\/li>\n<li>\u00a0In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour, which meets the requirements of visiting a patient at home and body examination.<\/li>\n<\/ol>\n<div><strong>Specification :<\/strong>\u00a0<strong>\u00a0<\/strong><br \/>\n|\u00a0<strong>Input mode<\/strong>\u00a0<strong>:<\/strong>\u00a0floating and defibrillation protection<br \/>\n|\u00a0<strong>Lead<\/strong>\u00a0<strong>:<\/strong>\u00a0standard 12-lead<br \/>\n|\u00a0<strong>Patient leak current<\/strong>\u00a0<strong>:<\/strong>\u00a0&lt; 10 \u00b5A<br \/>\n|\u00a0<strong>Input impedance<\/strong>\u00a0<strong>:<\/strong>\u00a0\u2265 2.5 M\u03a9<br \/>\n|\u00a0<strong>Time constant<\/strong>\u00a0<strong>:<\/strong>\u00a0\u2265 3.2 s<br \/>\n|\u00a0<strong>CMRR<\/strong>\u00a0<strong>:<\/strong>\u00a0&gt; 105 dB<br \/>\n|\u00a0<strong>Recording mode<\/strong>\u00a0<strong>:<\/strong>\u00a0thermal printing system<br \/>\n|\u00a0<strong>Paper size<\/strong>\u00a0<strong>:<\/strong>\u00a0210 mm (W) \u00d7 20 m (L), high-speed thermal paper<br \/>\n|\u00a0<strong>Paper speed<\/strong>\u00a0<strong>:<\/strong>\u00a012.5 mm\/s, 25 mm\/s, 50 mm\/s, error: \u00b1 5 %<br \/>\n|\u00a0<strong>Gain (sensitivity)<\/strong>\u00a0<strong>:<\/strong>\u00a05, 10, 20 mm \/ mV, accuracy: \u00b1 2 %<br \/>\n|\u00a0<strong>Standard sensitivity<\/strong>\u00a0<strong>:<\/strong>\u00a010 mm\/mV \u00b1 0.2 mm\/mV<br \/>\n|\u00a0<strong>Record mode<\/strong>\u00a0<strong>:<\/strong>\u00a0auto, rhythm and manual record<br \/>\n|\u00a0<strong>Measurement parameters<\/strong>\u00a0<strong>:<\/strong>\u00a0HR, P &#8211; R interval, P Duration, QRS Duration, T Duration, Q &#8211; T interval, Q &#8211; Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude<br \/>\n|\u00a0<strong>Safety class<\/strong>\u00a0<strong>:<\/strong>\u00a0class I, defibrillation-proof type CF applied part<br \/>\n|\u00a0<strong>Polarizing voltage<\/strong>\u00a0<strong>:<\/strong>\u00a0\u00b1 610 mV<br \/>\n|\u00a0<strong>Noise level<\/strong>\u00a0<strong>:<\/strong>\u00a0\u2264 12 \u00b5Vp-p<br \/>\n|\u00a0<strong>Sampling frequency for ECG signal input<\/strong>\u00a0<strong>:<\/strong>\u00a0 32 kHz<br \/>\n|\u00a0<strong>Sampling frequency for waveform data processing :<\/strong>\u00a01 kHz<br \/>\n|\u00a0<strong>Pacemaker detection channel<\/strong>\u00a0<strong>:<\/strong>\u00a0II<br \/>\n|\u00a0<strong>Time deviation in each channel<\/strong>\u00a0<strong>:<\/strong>\u00a0&lt;100 \u00b5s<br \/>\n|\u00a0<strong>Power supply<\/strong>\u00a0<strong>:<\/strong><\/div>\n<ul>\n<li>AC: 100V ~ 240V (50 \/ 60 Hz)<\/li>\n<li>DC: 14.8 V \/ 5200 mAh rechargeable lithium battery<\/li>\n<\/ul>\n<div>|\u00a0<strong>Working mode<\/strong>\u00a0<strong>:<\/strong>\u00a0Continuous operation<strong>\u00a0\u00a0<\/strong><\/div>\n<div><\/div>\n<\/div>\n<div><\/div>\n<div>\n<p><iframe title=\"CONTEC ECG1212G 12 Channels Electrocardiograph 12 lead ECG Clinical Hospital Use\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/GfhSQPlS6n0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Electrocardiograph Touch Screen ECG1212G The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto \/ manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for \u201cLead off\u201d and \u201cLack of paper\u201d; optional interface&hellip;<\/p>\n","protected":false},"featured_media":16435,"comment_status":"open","ping_status":"closed","template":"","meta":[],"pwb-brand":[],"product_brand":[],"product_cat":[150,112,151],"product_tag":[],"class_list":{"0":"post-16433","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-emergency","7":"product_cat-hospital","8":"product_cat-icu-rooms","9":"description-off","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"brands":[],"_links":{"self":[{"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/product\/16433","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/comments?post=16433"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/media\/16435"}],"wp:attachment":[{"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/media?parent=16433"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/pwb-brand?post=16433"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/product_brand?post=16433"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/product_cat?post=16433"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cmcpal.com\/site\/wp-json\/wp\/v2\/product_tag?post=16433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}