ECG600G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.

Function : 

  1.  Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
  2.  Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
  3.  Full-digital filter design, anti-baseline drift, AC and EMG interference.
  4.  Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
  5.  In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
  6.  Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
  7.  With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
Specification :
Display : 7” TFT-LCD
Mode : Real-time and continuously record the clear and accurate ECG waveform and annotation character (including lead mark, sensitivity, paper speed and filter state, etc.)
Measurement parameters : HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5) +S(V1)
Input mode : floating and defibrillation protection
Frequency response :  0.05Hz ~ 150Hz(-3dB~+0.4dB)
Time constant : ≥ 3.2s
Patient leak current : <10µA
Calibration voltage : 1mV
Noise level : <15µVp-p
Storge : More than 1000 cases, convenient for case review and statistic.
Sensitivity : 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Sampling accuracy 12-bit
Safety classification : class I, type CF and defibrillation-proof applied part
Recording mode :  thermal printing system
Auto record : Set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Paper size : 80mm(W)×20m(L)
Sampling frequency : 1000Hz
Dimension : 315mm(L) × 215mm(W) × 92mm(H)
Weigh : 1.7Kg