Electrocardiogram Holter / TLC5000
Electrocardiogram Holter / TLC5000
Electrocardiogram Holter / TLC5000
Description:
Electrocardiogram Holter
TLC5000
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function :
- The recorder can real-time store ECG data for 24-hour.
- Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
- Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
- With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
- Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
- Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
- All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
- With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
- Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
- With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
Technical Specification :
| Number of channels : 12 channels
| Sampling accuracy : 12Bit
| Record time : 24 h
| Power : 2 AA size batteries
| Interface : USB2.0
| Scale voltage : 1mV±5%
| Standard Sensitivity : 10mm/mV±5%
| Noise level : ≤30µV
| CMRR : ≥60dB
| Low-frequency characteristics : Time constant≥3.2s
| Scan speed : 25mm/s±5%
| Enduring polarization voltage : ±300mV DC polarization voltage, sensitivity shift≤±10%
| Least measure signal : 50 µV p-p
| Product safety type : Type B (Internally powered)
| Dimension : 111(L) X 60(W) X 25(H)mm
| Weight : About 105g (without battery)
| Number of channels : 12 channels
| Sampling accuracy : 12Bit
| Record time : 24 h
| Power : 2 AA size batteries
| Interface : USB2.0
| Scale voltage : 1mV±5%
| Standard Sensitivity : 10mm/mV±5%
| Noise level : ≤30µV
| CMRR : ≥60dB
| Low-frequency characteristics : Time constant≥3.2s
| Scan speed : 25mm/s±5%
| Enduring polarization voltage : ±300mV DC polarization voltage, sensitivity shift≤±10%
| Least measure signal : 50 µV p-p
| Product safety type : Type B (Internally powered)
| Dimension : 111(L) X 60(W) X 25(H)mm
| Weight : About 105g (without battery)